Retail · Bandar Kuala Ketil
PETRONAS Station Bandar Kuala Ketil
GreenRE Silver for a retail petrol station in Kedah, with renewable energy taking a full 20 of 20 points and lighting a full 12 of 12.
- Points awarded out of 120 under GreenRE NRB v4.0
- 91.95
- Renewable energy at full marks
- 20 / 20
- Artificial lighting efficiency
- 12 / 12
- Concrete Usage Index
- 5 / 5
The project
A two-storey retail petrol station in Bandar Kuala Ketil, Kedah, developed by Jesin Synergy, with 1,640 m² of gross floor area. Small buildings are not easier to certify than large ones. With little floor area to spread credits across, each one has to carry more weight.
What the assessment found
Renewable energy took the full 20 of 20 points. It was the single largest contributor to the score, and the credit that made Silver reachable on a building of this size.
Artificial lighting achieved a full 12 of 12 and car park ventilation 4 of 4. Common-area daylighting reached 2 of 3 and common-area ventilation 3.50 of 5. EEI computation took its full point, which matters on an operating retail asset: it means performance is being measured rather than assumed.
The envelope scored 8.58 of 15 on OTTV, and the air-cooled chilled-water and unitary air-conditioning pathway 15.60 of 20.
On water, efficient fittings reached 7.27 of 8 with drought-tolerant planting taking its point. Construction scored a full 5 of 5 on the Concrete Usage Index.
Outcome
GreenRE Silver, assessed 7 April 2026 and approved 30 April 2026, at 91.95 of 120 points.
A petrol station is an unglamorous building type and an instructive one. The result came from getting the big-ticket credits right, generation and lighting, rather than from chasing every available point.
Assessment result
What this building scored, credit by credit
Most consultancies publish a rating and a photograph. This is the assessment itself: awarded against available, criterion by criterion, so you can see where the points came from and where they were left on the table. Assessed under GreenRE Non-Residential Building, NRB v4.0, final result 91.95 of 120 points, GreenRE Silver (assessed 7 April 2026, approved 30 April 2026).
| Criterion | Awarded | Available |
|---|---|---|
| OTTV | 8.58 | 15 |
| Air-conditioning systems | 15.60 | 20 |
| Common-area daylighting | 2 | 3 |
| Artificial lighting | 12, full marks | 12 |
| Car park ventilation | 4, full marks | 4 |
| Common-area ventilation | 3.50 | 5 |
| EEI computation | 1, full marks | 1 |
| Renewable energy | 20, full marks | 20 |
| Water-efficient fittings | 7.27 | 8 |
| Drought-tolerant planting | 1, full marks | 1 |
| Concrete Usage Index | 5, full marks | 5 |
| Sustainable products | 1 | 8 |
| Environmental management | 5 | 10 |
| Public transport accessibility | 1, full marks | 1 |
| EV charging and priority parking | 1, full marks | 1 |
| Noise | 1, full marks | 1 |
| Low-VOC paints | 1, full marks | 1 |
| Carbon emission assessment | 2 | 3 |